- 1865+ Megohmmeter- Discontinued Replaced by the 1888
Discontinued becuase of parts obsolense as of July 2024
Replaced by the more accuracte easier to use 1888
CLICK HERE FOR THE 1888 Megohmeter
IET can still calibrate and repair most issues
- esi SR1010 Resistance Transfer Standard
- Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
- Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
- Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
- Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
- Long Term Accuracy... ± 50PPM of nominal value
- Calibration Accuracy... ± 10PPM
- HRRS-5 kV & 10 kV Series - High Resistance Decade Box
- Choose from units with a max. resistance of 1 GΩ, 10 GΩ, 10 GΩ, 1TΩ or 11 TΩ
- Units use the most stable and accurate resistors and custom high voltage switches
- Maximum Voltages of 5000 V or 10,000 V. For 2000 V, consider the standard HRRS Series
- Used for calibration of Meggers and sourcing out precision high resistance.
- OS-260 & OS-270 Resistance Decade Boxes / RTD Simulator
- The revolutionary ohmSOURCE microprocessor controlled resistor is like nothing you have ever seen before!
- US Patent 6487456
- Two cost-effective models available
- Accuracy's as tight as 0.01%, with resolution as good as 0.01Ω
- Engineered as an ideal RTD calibrator
- Unit can only be used as a MANUAL unit. Can not be connected to or controlled by a computer
- PRS-200 Series Programmable Resistance Decade Box
- IEEE, RS232 or Ethernet Programmable Decade Resistor
- Wide range and resolution: 1 mΩ to 100 MΩ
- Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
- Special RTD and custom configurations
- Dual / Combo rackmount models ( examples: Resistance & Capacitance or Resistance & Inductance)
- SR102/103/104 Series
- Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
- Lowest temperature coefficients (< 0.1 ppm/ºC)
- Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
- Has remained the foremost resistance standard, with no equivalent, for over 35 years
- 5 Year Warranty Included
- VRS-100 Series High Resistance Standards
- Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
- High Accuracy - up to 20 ppm
- Standard voltage: up to 5 kV (voltages of 10 kV are available)
- Excellent for calibration of Meggers
- For higher resistance values above 10 TΩ see SRC-T Network Standards