IET

  1. CS Series Cost Effective Capacitance Decade Box
    • Accurate 0.5% to 4%
    • Wide range from 50 pF - 1000 µF (depending on model)
    • Resolutions as good as 1 pF (depending on model)
    • Broad choice of standard and optional models with many powerful features
    • Compact, convenient, and rugged
  2. DCCS DC Current Shunt Series
    • Allows for high current calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High accuracy 0.02%
    • Suitable for direct current & audio frequencies
    • Oil-filled design ensures great long term stability <0.01% over many years
  3. HRRS-5 kV & 10 kV Series - High Resistance Decade Box
    • Choose from units with a max. resistance of 1 GΩ, 10 GΩ, 10 GΩ, 1TΩ or 11 TΩ
    • Units use the most stable and accurate resistors and custom high voltage switches
    • Maximum Voltages of 5000 V or 10,000 V. For 2000 V, consider the standard HRRS Series
    • Used for calibration of Meggers and sourcing out precision high resistance.
  4. OS-260 & OS-270 Resistance Decade Boxes / RTD Simulator
    • The revolutionary ohmSOURCE microprocessor controlled resistor is like nothing you have ever seen before!
    • US Patent 6487456
    • Two cost-effective models available
    • Accuracy's as tight as 0.01%, with resolution as good as 0.01Ω
    • Engineered as an ideal RTD calibrator 
    • Unit can only be used as a MANUAL unit. Can not be connected to or controlled by a computer
  5. PRS-200 Series Programmable Resistance Decade Box
    • IEEE, RS232 or Ethernet Programmable Decade Resistor
    • Wide range and resolution: 1 mΩ to 100 MΩ
    • Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
    • Special RTD and custom configurations
    • Dual / Combo rackmount models ( examples: Resistance & Capacitance or Resistance & Inductance)
  6. RTD Series - Precision RTD Simulator
    • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
    • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
    • Resolution: 1 mΩ (0.0025 ºC for PT 100)
    • Stability 0.0002% for 24 hours; 0.001% for 12 months
  7. SCA Series Capacitance Standard
    • Values from 1 pF to 10,000 µF in any custom value available
    • Stability as good as ±0.01 %/year
    • Two-to-five terminal configuration, depending on model
    • Excellent TC: as low as 10 ppm/°C
    • 3 year warranty included
  8. SRX-NI-4082 Standard Resistor Calibration Set
    • Owned used and recommend by National Instruments
    • Very stable - drift < 50 ppm/yr
    • Excellent temperature coefficient - 2 ppm/°C
    • Rugged
    • Set consists of 4 resistance standards: 25 Ω, 125 Ω, 5 kΩ, 100 kΩ values as recommended by NI PXIe-408x calibration procedure
    • 3/4" spacing for direct connection to the NI PXIe-4082
    • Low inductance < 0.08 µH
    • Accredited Calibration
    • In addition to the standard values, any custom value is available.  Please contact the IET sales department, for more information
  9. VI-700 Precision Voltage & Current Source (Discontinued)
    • Discontinued
    • Voltage output range of 100 µV to 20 V or 200 V
    • Current output range of 0.1 µA to 20 mA or 200 mA
    • 3½ digit resolution, 0.75 LSD accuracy
    • Manual thumbwheel operation or programmable digital input, IEEE-488 or RS232 interface
    • May be used as a component in a closed loop control system
    • Manufactured in the United States

17 Items

Set Descending Direction